Jeasins programmable temperature and humidity control system can be introduced testing machine |
Date:2015/06/30 Read:1735 |
Programmable temperature and humidity control system can test machine uses touch-screen temperature controller. 1, control: Touch 2, Display: Korea TMIE880 programmable CLCD color LCD display. 3, system capacity: 120 Group X100 program segment, the number of segments of the desired program can be arbitrarily divided each group, each group is free to link the program and each other. 4, cycle setting: Each run executables, 9999 return or repeated countless cycles of, and may be further divided to the extent hindered Paragraph 5 to perform extra part of the cycle. 5, the operating mode: setting / program / Quick, three operating modes in line with the implementation of a variety of temperature conditions of the test. 6, control: intelligent microcomputer PID + SSR / SCR forward and inverse two-way automatic synchronization output. 7, the data set: built-in applications catalog management, facilitate the establishment of the test name and program data, the change, access to, or operation of the line. 8, curve drawing: data setup is complete data set can be made of the curve immediately informed of the actual operation can run the curve of the drawing screen. 9, the timing control: 2 groups timing output control interface, with 10 kinds of time control mode, the drive assembly for external logic to perform a timing plan to start / stop it. 10. Reservation starts: all test conditions set reservation function Jieke start running it. 11, the operation lock: You can lock the function of start and stop conditions, prevent other people inadvertently affect the results. 12, power reset: temperature and humidity testing equipment off and then start the pattern memory means and opportunity to re-power station of 12.1.BREAK (interrupt), 12.2.COLD (cold start), 12.3.HOT (heat engine start). 13, security detector: temperature and humidity testing machine's built-in full-featured system 15 detection sensing device in order to ensure safe operation of the machine, when the perception of abnormal power failure immediately cut off the control of the machine, and automatically displays the fault Remedy projects and time of occurrence, abnormality. 14, abnormal traced: to display the history data is abnormal Fault. 15, external protection: independent of the electronic over-temperature protection device One controller of the only. 16, Communication Interface: RS-232 of the standard communication interface device can be used with a personal computer (PC) at the same time online multi-machine control and management. 17, display switching: Chinese / English display subtitles, you can switch freely. |
Previous: | Next: Ten Humidity Chamber Laboratory Management System Reference Standard |
|